Vulnerability  oval:org.mitre.oval:def:19758
HP Serviceguard, Remote Denial of Service (DoS)  

Unspecified vulnerability in HP Serviceguard A.11.19 and A.11.20 allows remote attackers to cause a denial of service via unknown vectors.
Create Date: 2013-11-30 Last Update Date: 2015-04-20

Affected Platforms/Products

Affected Products (CPE + CVE references)
Platforms: unix (from OVAL definitions)
  • HP-UX 11

References

Criteria

The system is vulnerable
IF : Any one of the following are true
IF : All of the following are true Criteria meets HP Security Bulletin HPSBUX02806
IF : NOT Patch PHSS_43094 is installed
hpux : patch53_test :  Patch PHSS_43094 is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : Patch 
behaviors : [ supersedence=true ]
swtype : PH
area_patched : SS
patch_base : 43094
IF : HP-UX B.11.31
Uname Test :  HP-UX B.11.31 
At least one of the objects listed below must exist on the system (Existence check)
Unix : uname Object The single uname object.
Output of "uname -a"
os_release (equals) B.11.31
unix : uname_state 
IF : Any one of the following are true filesets tests
IF : SGManagerPI.SGMGRPI is installed
hpux : swlist_test :  SGManagerPI.SGMGRPI is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGManagerPI.SGMGRPI
IF : Cluster-OM.CM-DEN-MOF is installed
hpux : swlist_test :  Cluster-OM.CM-DEN-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-DEN-MOF
IF : Cluster-OM.CM-DEN-PROV is installed
hpux : swlist_test :  Cluster-OM.CM-DEN-PROV is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-DEN-PROV
IF : Cluster-OM.CM-OM-TOOLS is installed
hpux : swlist_test :  Cluster-OM.CM-OM-TOOLS is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-TOOLS
IF : Cluster-OM.CM-OM-AUTH-COM is installed
hpux : swlist_test :  Cluster-OM.CM-OM-AUTH-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-AUTH-COM
IF : Cluster-OM.CM-OM-AUTH is installed
hpux : swlist_test :  Cluster-OM.CM-OM-AUTH is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-AUTH
IF : Cluster-OM.CM-OM-COM is installed
hpux : swlist_test :  Cluster-OM.CM-OM-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-COM
IF : Cluster-OM.CM-OM is installed
hpux : swlist_test :  Cluster-OM.CM-OM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM
IF : CM-Provider-MOF.CM-MOF is installed
hpux : swlist_test :  CM-Provider-MOF.CM-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : CM-Provider-MOF.CM-MOF
IF : CM-Provider-MOF.CM-PROVIDER is installed
hpux : swlist_test :  CM-Provider-MOF.CM-PROVIDER is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : CM-Provider-MOF.CM-PROVIDER
IF : SGWBEMProviders.SGPROV-CORE-COM is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-CORE-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-CORE-COM
IF : SGWBEMProviders.SGPROV-DOC is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-DOC is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-DOC
IF : SGWBEMProviders.SGPROV-MOF is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-MOF
IF : SGWBEMProviders.SGPROV-CORE is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-CORE is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-CORE
IF : Package-CVM-CFS.CM-CVM-CFS-COM is installed
hpux : swlist_test :  Package-CVM-CFS.CM-CVM-CFS-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-CVM-CFS.CM-CVM-CFS-COM
IF : Package-CVM-CFS.CM-CVM-CFS is installed
hpux : swlist_test :  Package-CVM-CFS.CM-CVM-CFS is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-CVM-CFS.CM-CVM-CFS
IF : Package-Manager.CM-PKG-COM is installed
hpux : swlist_test :  Package-Manager.CM-PKG-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-Manager.CM-PKG-COM
IF : Cluster-Monitor.CM-CORE-COM is installed
hpux : swlist_test :  Cluster-Monitor.CM-CORE-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-Monitor.CM-CORE-COM
IF : Package-Manager.CM-PKG is installed
hpux : swlist_test :  Package-Manager.CM-PKG is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-Manager.CM-PKG
IF : Cluster-Monitor.CM-CORE is installed
hpux : swlist_test :  Cluster-Monitor.CM-CORE is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-Monitor.CM-CORE
IF : All of the following are true Criteria meets HP Security Bulletin HPSBUX02806
IF : HP-UX B.11.31
Uname Test :  HP-UX B.11.31 
At least one of the objects listed below must exist on the system (Existence check)
Unix : uname Object The single uname object.
Output of "uname -a"
os_release (equals) B.11.31
unix : uname_state 
IF : NOT Patch PHSS_42988 is installed
hpux : patch53_test :  Patch PHSS_42988 is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : Patch 
behaviors : [ supersedence=true ]
swtype : PH
area_patched : SS
patch_base : 42988
IF : Any one of the following are true filesets tests
IF : SGManagerPI.SGMGRPI is installed
hpux : swlist_test :  SGManagerPI.SGMGRPI is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGManagerPI.SGMGRPI
IF : SGWBEMProviders.SGPROV-MOF is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-MOF
IF : SGWBEMProviders.SGPROV-CORE is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-CORE is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-CORE
IF : Cluster-OM.CM-OM-COM is installed
hpux : swlist_test :  Cluster-OM.CM-OM-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-COM
IF : Cluster-OM.CM-DEN-MOF is installed
hpux : swlist_test :  Cluster-OM.CM-DEN-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-DEN-MOF
IF : CM-Provider-MOF.CM-MOF is installed
hpux : swlist_test :  CM-Provider-MOF.CM-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : CM-Provider-MOF.CM-MOF
IF : Cluster-OM.CM-OM-AUTH-COM is installed
hpux : swlist_test :  Cluster-OM.CM-OM-AUTH-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-AUTH-COM
IF : Cluster-OM.CM-DEN-PROV is installed
hpux : swlist_test :  Cluster-OM.CM-DEN-PROV is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-DEN-PROV
IF : CM-Provider-MOF.CM-PROVIDER is installed
hpux : swlist_test :  CM-Provider-MOF.CM-PROVIDER is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : CM-Provider-MOF.CM-PROVIDER
IF : Cluster-OM.CM-OM-TOOLS is installed
hpux : swlist_test :  Cluster-OM.CM-OM-TOOLS is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-TOOLS
IF : Cluster-OM.CM-OM-AUTH is installed
hpux : swlist_test :  Cluster-OM.CM-OM-AUTH is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-AUTH
IF : Cluster-OM.CM-OM is installed
hpux : swlist_test :  Cluster-OM.CM-OM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM
IF : Package-CVM-CFS.CM-CVM-CFS-COM is installed
hpux : swlist_test :  Package-CVM-CFS.CM-CVM-CFS-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-CVM-CFS.CM-CVM-CFS-COM
IF : Cluster-Monitor.CM-CORE-COM is installed
hpux : swlist_test :  Cluster-Monitor.CM-CORE-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-Monitor.CM-CORE-COM
IF : Package-Manager.CM-PKG-COM is installed
hpux : swlist_test :  Package-Manager.CM-PKG-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-Manager.CM-PKG-COM
IF : Package-Manager.CM-PKG is installed
hpux : swlist_test :  Package-Manager.CM-PKG is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-Manager.CM-PKG
IF : Cluster-Monitor.CM-CORE is installed
hpux : swlist_test :  Cluster-Monitor.CM-CORE is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-Monitor.CM-CORE
IF : Package-CVM-CFS.CM-CVM-CFS is installed
hpux : swlist_test :  Package-CVM-CFS.CM-CVM-CFS is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-CVM-CFS.CM-CVM-CFS
IF : All of the following are true Criteria meets HP Security Bulletin HPSBUX02806
IF : NOT Patch PHSS_42987 is installed
hpux : patch53_test :  Patch PHSS_42987 is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : Patch 
behaviors : [ supersedence=true ]
swtype : PH
area_patched : SS
patch_base : 42987
IF : HP Release B.11.23
Uname Test :  HP-UX B.11.23 
At least one of the objects listed below must exist on the system (Existence check)
Unix : uname Object The single uname object.
Output of "uname -a"
os_release (equals) B.11.23
unix : uname_state 
IF : Any one of the following are true filesets tests
IF : SGWBEMProviders.SGPROV-MOF is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-MOF
IF : SGManagerPI.SGMGRPI is installed
hpux : swlist_test :  SGManagerPI.SGMGRPI is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGManagerPI.SGMGRPI
IF : SGWBEMProviders.SGPROV-CORE is installed
hpux : swlist_test :  SGWBEMProviders.SGPROV-CORE is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : SGWBEMProviders.SGPROV-CORE
IF : Cluster-OM.CM-OM-COM is installed
hpux : swlist_test :  Cluster-OM.CM-OM-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-COM
IF : Cluster-OM.CM-DEN-MOF is installed
hpux : swlist_test :  Cluster-OM.CM-DEN-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-DEN-MOF
IF : CM-Provider-MOF.CM-MOF is installed
hpux : swlist_test :  CM-Provider-MOF.CM-MOF is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : CM-Provider-MOF.CM-MOF
IF : Cluster-OM.CM-OM-AUTH-COM is installed
hpux : swlist_test :  Cluster-OM.CM-OM-AUTH-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-AUTH-COM
IF : Cluster-OM.CM-DEN-PROV is installed
hpux : swlist_test :  Cluster-OM.CM-DEN-PROV is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-DEN-PROV
IF : CM-Provider-MOF.CM-PROVIDER is installed
hpux : swlist_test :  CM-Provider-MOF.CM-PROVIDER is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : CM-Provider-MOF.CM-PROVIDER
IF : Cluster-OM.CM-OM-TOOLS is installed
hpux : swlist_test :  Cluster-OM.CM-OM-TOOLS is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-TOOLS
IF : Cluster-OM.CM-OM-AUTH is installed
hpux : swlist_test :  Cluster-OM.CM-OM-AUTH is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM-AUTH
IF : Cluster-OM.CM-OM is installed
hpux : swlist_test :  Cluster-OM.CM-OM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-OM.CM-OM
IF : Package-CVM-CFS.CM-CVM-CFS-COM is installed
hpux : swlist_test :  Package-CVM-CFS.CM-CVM-CFS-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-CVM-CFS.CM-CVM-CFS-COM
IF : Package-CVM-CFS.CM-CVM-CFS is installed
hpux : swlist_test :  Package-CVM-CFS.CM-CVM-CFS is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-CVM-CFS.CM-CVM-CFS
IF : Package-Manager.CM-PKG is installed
hpux : swlist_test :  Package-Manager.CM-PKG is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-Manager.CM-PKG
IF : Cluster-Monitor.CM-CORE-COM is installed
hpux : swlist_test :  Cluster-Monitor.CM-CORE-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-Monitor.CM-CORE-COM
IF : Package-CVM-CFS.CM-CVM-CFS is installed
hpux : swlist_test :  Package-CVM-CFS.CM-CVM-CFS is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-CVM-CFS.CM-CVM-CFS
IF : Package-Manager.CM-PKG is installed
hpux : swlist_test :  Package-Manager.CM-PKG is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-Manager.CM-PKG
IF : Package-Manager.CM-PKG-COM is installed
hpux : swlist_test :  Package-Manager.CM-PKG-COM is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Package-Manager.CM-PKG-COM
IF : Cluster-Monitor.CM-CORE is installed
hpux : swlist_test :  Cluster-Monitor.CM-CORE is installed 
At least one of the objects listed below must exist on the system (Existence check)
HP UX : SWList 
swlist : Cluster-Monitor.CM-CORE

Quick Help

Other Help Topics
Data Types
What is an Object?
What is a State?
What is a Test?
Other Help Topics
Regular Expression Patterns
Some object or state definitions are defined as regular expression patterns, you should interpret the regexp pattern while evaluating them.

OVAL Definitions By Referenced Objects

How does it work?   User agreement and privacy statement   About & Contact
CVE is a registred trademark of the MITRE Corporation and the authoritive source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritive source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritive source of OVAL content is MITRE's OVAL web site.
Warning: This site and all data are provided as is. It is not guaranteed that all information is accurate and complete. Use any information provided on this site at your own risk. By using this site you accept that you know that these data are provided as is and not guaranteed to be accurate, correct or complete. All trademarks appearing on this site are the property of their respective owners in the US or other countries. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss. PLEASE SEE nvd.nist.gov and oval.mitre.org for more details about OVAL language and definitions.
The information within this database may change without notice. Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. In no event shall the author/distributor/web site owner/maintainer be held liable for any damages whatsoever arising out of or in connection with the use or spread of this information.
Use of OVAL and all related data is subject to terms of use defined by Mitre at http://oval.mitre.org/oval/about/termsofuse.html